RPT's advanced solution for plugging and carry over problems - vertical gas flow

Design:
The comnied tubular/roof mist eliminator is a full two level mist eliminator which is installed on a sigle layer support structure. The
demister wash system - wash headers and pipe supports - is part of the supply.
This very compact design requires only 1500 mm of height including the supoort beam.
The three level mist eliminator is of particular interest for FGD that have to meet the future emission standards - lowest
particulate emission. This design with a tubular and two lamella mist eliminator outperforms a conventional threee level lamella
mist leiminator, but only has the height of 3300 mm including the support beams.
Function and characteristics:
- For seperation in vertical gas flow
- As replacement for a coarse mist eliminator built from lamella
- As a complete third mist eliminator when upgrading from two to three levels
- Well be configured for the specific operating conditions
- 2 or 3 levels of tubes
- Variable pitch of tubes
Advantages of RPT's desing:
Lowest total height possible
No plugging and clogging
Very good seperation performance
No upstream washing required
Simple and easy retrofit for existing FGD
No changes of steel structure or wall penetrations required
RPT's combination of a tubular coarse and one or two lamella fine mist eliminators is a very efficient and lowest cost concept for future FGD.